ATAGO's Multi-Wavelength Abbe Refractometers have the ability to measure liquids or solids at different wavelengths using interchangeable filters. Measurements are displayed digitally for easy reading.

Multi-Wavelength Abbe Refractometer DR-M2

Refractive index or Abbe number ( νd or νe ) can be measured at different wavelengths ranging from 450 to 1,100nm.
The DR-M2 digitally displays measurement result of refractive index or Abbe number on the LCD.
Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs.
This refractometer is connectable with Digital printer DP-22 (B) (Optional).


Enlargement
Quantity
>about the icons Can be connected to a circulating constant temperature bath Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model DR-M2 Cat.No. 1410
Measurement Range Refractive index 1.3278 to 1.7379 ( Wavelength 450nm )
Refractive index 1.3000 to 1.7100 ( Wavelength 589nm )
Refractive index 1.2912 to 1.7011 ( Wavelength 680nm )
Refractive index 1.2743 to 1.6840 ( Wavelength 1,100nm )
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index : ±0.0002
( With the attached test piece at 589nm )
Wavelength Range From 450 to 1100nm ( with interference filters )
( For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer ( Optional ) is required )
Measurement
Temperature Range
5 to 50°C Output Terminal For printer, DP-22 (B) (Optional)
Power Supply AC100 to 240V 50/60Hz Power Consumption 160VA
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.0kg (Light source unit)
Optional Lighting glass for film measuerment (for DR-M2) : RE-6191
Digital printer DP-22(B) : Cat.No.3125
• Interference filter

589(D)nm : RE-3520
486(F)nm : RE-3521
656(C)nm : RE-3522
546(e)nm : RE-3523
480(F')nm : RE-3524
644(C')nm : RE-3525
(select one wavelength) : RE-3526

450 to 539nm
540 to 680nm
681 to 799nm
800 to 1110nm

• Near-infrared ray viewer : RE-9119
• Eyepiece for polarizing : RE-1146
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Test piece A with m-naphthalene : RE-1195
• Main & secondary prism for DR-M2 : RE-1600
• Illuminating lamp for DR-M2, M4 : RE-4170
• Pack of desiccant tablets : RE-1592
Catalog Download
Go to the product search GO TOP

Multi-Wavelength Abbe Refractometer DR-M4

Refractive index or Abbe number ( νd or νe ) can be measured at different wavelengths ranging from 450 to 1,100nm ( For measurement at wavelengths ranging from 681 to 1,100nm, the Optional Near Infrared Ray Viewer ( RE-9119 ) is required. )
The DR-M4 displays measurement result of refractive index or Abbe number digitally on the LCD.
Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs.
This refractometer is connectable with Digital printer DP-22 (B) (Optional).


Enlargement
Quantity
>about the icons Can be connected to a circulating constant temperature bath Digital display AC outlet (AC100 to 240V) Refractive index scale
Model DR-M4 Cat.No. 1414
Measurement Range Refractive index 1.5219 to 1.9220 ( Wavelength 450nm )
Refractive index 1.4700 to 1.8700 ( Wavelength 589nm )
Refractive index 1.4545 to 1.8544 ( Wavelength 680nm )
Refractive index 1.4260 to 1.8259 ( Wavelength 1,100nm )
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index : ±0.0002
( With the attached test piece at 589nm )
Wavelength Range From 450 to 1100nm ( with interference filters )
( For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer ( Optional ) is required )
Measurement
Temperature Range
5 to 50°C Output Terminal For printer, DP-22(B) (Optional)
Power Consumption 160VA Power Supply AC100 to 240V 50/60Hz
Dimensions & Weight 13×29×31cm, 6.0kg ( Refractometer )
15×33×11cm, 3.0kg ( Light source unit )
Optional Lighting glass for film measuerment (for DR-M4) : RE-6193
Digital printer DP-22(B) : Cat.No.3125
• Interference filter

589(D)nm :RE-3520
486(F)nm :RE-3521
656(C)nm :RE-3522
546(e)nm :RE-3523
480(F')nm :RE-3524
644(C')nm :RE-3525
(select one wavelength) : RE-3526

450 to 539nm
540 to 680nm
681 to 799nm
800 to 1110nm

• Near-infrared ray viewer :RE-9119
• Eyepiece for polarizing : RE-1146
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Test piece C with m-naphthalene : RE-1197
• Main & secondary prism for DR-M4, DR-M4/1550 : RE-1640
• Illuminating lamp for DR-M2, M4 : RE-4170
• Pack of desiccant tablets : RE-1592
Catalog Download
Go to the product search GO TOP

Multi-Wavelength Abbe Refractometer DR-M2/1550(A)     < AC200 to 240V >

Refractive index or Abbe number ( νd or νe ) can be measured at different wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-22 (B) (Optional).


Enlargement
Quantity
>about the icons Can be connected to a circulating constant temperature bath Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model DR-M2/1550(A) Cat.No. 1412
Measurement Range Refractive index 1.3278 to 1.7379 ( at 450nm )
Refractive index 1.3000 to 1.7100 ( at 589nm )
Refractive index 1.2912 to 1.7011 ( at 680nm )
Refractive index 1.2743 to 1.6840 ( at 1,100nm )
Refractive index 1.2662 to 1.6759 ( at 1,550nm )
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index : ±0.0002
( With the attached test piece at 589nm )
Wavelength Range 450 to 1550nm
*With interference filters
Measurement
Temperature Range
5 to 50°C
Main Components Refractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter ( 589nm ).
Output Terminal For printer, DP-22(B) (Optional) Light source Monochromatic light source device
Dimensions & Weight :23×35×21 to 31cm, 5.9kg
Power Supply AC100 to 240V 50/60Hz
Monochromatic light source device AC 200 to 240V 50/60Hz
Power Consumption 100VA(Refractometer, Power supply unit)
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.0kg (Power supply unit)
Optional Lighting glass for film measuerment (for DR-M2) : RE-6191
Digital printer DP-22(B) : Cat.No.3125
• Interference filter

589(D) nm : RE-16501
486(F) nm : RE-16502
656(C) nm : RE-16503
546(e) nm : RE-16504
480(F') nm : RE-16505
644(C') nm : RE-16506
(select one wavelength) : RE-16507
450 to 539nm
540 to 680nm
681 to 799nm
800 to 1550nm

• Frame for Interference Filter DR-M2/1550(A), DR-M4/1550(A)

589nm : RE-16511
486nm : RE-16512
656nm : RE-16513
546nm : RE-16514
480nm : RE-16515
644nm : RE-16516
Frame for Interference Filter of Optional :RE-16517

• Near-infrared ray viewer : RE-9119
• Eyepiece for polarizing : RE-1146
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Test piece A with m-naphthalene : RE-1195
• Main & secondary prism for DR-M2/1550(A) : RE-16500
• Pack of desiccant tablets : RE-1592
Catalog Download
Go to the product search GO TOP

Multi-Wavelength Abbe Refractometer DR-M2/1550(B)     < AC100 to 110V >

Refractive index or Abbe number ( νd or νe ) can be measured at different wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-22 (B) (Optional).


Enlargement
Quantity
>about the icons Can be connected to a circulating constant temperature bath Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model DR-M2/1550(B) Cat.No. 1413
Measurement Range Refractive index 1.3278 to 1.7379 ( at 450nm )
Refractive index 1.3000 to 1.7100 ( at 589nm )
Refractive index 1.2912 to 1.7011 ( at 680nm )
Refractive index 1.2743 to 1.6840 ( at 1,100nm )
Refractive index 1.2662 to 1.6759 ( at 1,550nm )
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index : ±0.0002
( With the attached test piece at 589nm )
Wavelength Range 450 to 1550nm
*With interference filters
Measurement
Temperature Range
5 to 50°C
Main Components Refractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter ( 589nm ).
Output Terminal For printer, DP-22(B) (Optional) Light source Monochromatic light source device
Dimensions & Weight :23×32×21 to 31cm, 5.0kg
Power Supply AC100 to 240V 50/60Hz
Monochromatic light source device AC 100 to 110V 50/60Hz
Power Consumption 100VA(Refractometer, Power supply unit)
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.0kg (Power supply unit)
Optional Lighting glass for film measuerment (for DR-M2) : RE-6191
Digital printer DP-22(B) : Cat.No.3125
• Interference filter

589(D) nm : RE-16501
486(F) nm : RE-16502
656(C) nm : RE-16503
546(e) nm : RE-16504
480(F') nm : RE-16505
644(C') nm : RE-16506
(select one wavelength) : RE-16507
450 to 539nm
540 to 680nm
681 to 799nm
800 to 1550nm

• Frame for Interference Filter DR-M2/1550(B), DR-M4/1550(B)

589nm : RE-16511
486nm : RE-16512
656nm : RE-16513
546nm : RE-16514
480nm : RE-16515
644nm : RE-16516
Frame for Interference Filter of Optional :RE-16517

• Near-infrared ray viewer : RE-9119
• Eyepiece for polarizing : RE-1146
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Test piece A with m-naphthalene : RE-1195
• Main & secondary prism for DR-M2/1550(B) : RE-16500
• Pack of desiccant tablets : RE-1592
Catalog Download
Go to the product search GO TOP

Multi-Wavelength Abbe Refractometer DR-M4/1550(A)     < AC200 to 240V >

Refractive index or Abbe number ( νd or νe ) can be measured atdifferent wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-22 (B) (Optional).


Enlargement
Quantity
>about the icons Can be connected to a circulating constant temperature bath Digital display AC outlet (AC100 to 240V) Refractive index scale
Model DR-M4/1550(A) Cat.No. 1415
Measurement Range Refractive index 1.5219 to 1.9155 ( at 450nm )
Refractive index 1.4700 to 1.8700 ( at 589nm )
Refractive index 1.4561 to 1.8544 ( at 680nm )
Refractive index 1.4310 to 1.8259 ( at 1,100nm )
Refractive index 1.4215 to 1.8136 ( at 1,550nm )
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index ±0.0002
(with the attached test piece at 589nm )
Wavelength Range From 450 to 1,550nm
( with interference filters )
Measurement
Temperature Range
5 to 50°C
Main Components Refractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter ( 589nm ) .
Output Terminal For printer, DP-22(B) (Optional) Light source Monochromatic light source device
Dimensions & Weight :23×35×21 to 31cm, 5.9kg
Power Supply AC100 to 240V 50/60Hz
Monochromatic light source device AC 200 to 240V 50/60Hz
Power Consumption 100VA(Refractometer, Power supply unit)
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.0kg (Power supply unit)
Optional Lighting glass for film measuerment (for DR-M4) : RE-6193
Digital printer DP-22(B) : Cat.No.3125
• DR-M2/1550(A), DR-M4/1550(A) Interference filter

589(D)nm : RE-16501
486(F)nm : RE-16502
656(C)nm : RE-16503
546(e)nm : RE-16504
480(F')nm : RE-16505
644(C')nm : RE-16506
(select one wavelength) : RE-16507
450 to 539nm
540 to 680nm
681 to 799nm
800 to 1550nm

• Frame for Interference Filter DR-M2/1550(A),DR-M4/1550(A)

589nm : RE-16511
486nm : RE-16512
656nm : RE-16513
546nm : RE-16514
480nm : RE-16515
644nm : RE-16516
Frame for Interference Filter of Optional : RE-16517

• Near-infrared ray viewer : RE-9119
• Eyepiece for polarizing : RE-1146
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Test piece C with m-naphthalene : RE-1197
• Main & secondary prism for DR-M4/1550(A) : RE-1640
• Pack of desiccant tablets : RE-1592
Catalog Download
Go to the product search GO TOP

Multi-Wavelength Abbe Refractometer DR-M4/1550(B)     < AC100 to 110V >

Refractive index or Abbe number ( νd or νe ) can be measured atdifferent wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-22 (B) (Optional).


Enlargement
Quantity
>about the icons Can be connected to a circulating constant temperature bath Digital display AC outlet (AC100 to 240V) Refractive index scale
Model DR-M4/1550(B) Cat.No. 1416
Measurement Range Refractive index 1.5219 to 1.9155 ( at 450nm )
Refractive index 1.4700 to 1.8700 ( at 589nm )
Refractive index 1.4561 to 1.8544 ( at 680nm )
Refractive index 1.4310 to 1.8259 ( at 1,100nm )
Refractive index 1.4215 to 1.8136 ( at 1,550nm )
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index ±0.0002
(with the attached test piece at 589nm )
Wavelength Range From 450 to 1,550nm
( with interference filters )
Measurement
Temperature Range
5 to 50°C
Main Components Refractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter ( 589nm ) .
Output Terminal For printer, DP-22(B) (Optional) Light source Monochromatic light source device
Dimensions & Weight :23×32×21 to 31cm, 5.0kg
Power Supply AC100 to 240V 50/60Hz
Monochromatic light source device AC 100 to 110V 50/60Hz
Power Consumption 100VA(Refractometer, Power supply unit)
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.0kg (Power supply unit)
Optional Lighting glass for film measuerment (for DR-M4) : RE-6193
Digital printer DP-22(B) : Cat.No.3125
• DR-M2/1550(B), DR-M4/1550(B) Interference filter

589(D)nm : RE-16501
486(F)nm : RE-16502
656(C)nm : RE-16503
546(e)nm : RE-16504
480(F')nm : RE-16505
644(C')nm : RE-16506
(select one wavelength) : RE-16507
450 to 539nm
540 to 680nm
681 to 799nm
800 to 1550nm

• Frame for Interference Filter DR-M2/1550(B),DR-M4/1550(B)

589nm : RE-16511
486nm : RE-16512
656nm : RE-16513
546nm : RE-16514
480nm : RE-16515
644nm : RE-16516
Frame for Interference Filter of Optional : RE-16517

• Near-infrared ray viewer : RE-9119
• Eyepiece for polarizing : RE-1146
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Test piece C with m-naphthalene : RE-1197
• Main & secondary prism for DR-M4/1550(B) : RE-1640
• Pack of desiccant tablets : RE-1592
Catalog Download
Go to the product search GO TOP

Circulating Constant Temperature Bath 60-C3

The 60-C3 is an external circulation type constant temperature water tank provided with a thermo-module. The temperature can be set in the range of 10 to 60°C and the unit is perfectly suited for connection with a refractometer.


Enlargement
Quantity
>about the icons Digital display AC outlet (AC100 to 240V)
Model 60-C3 Cat.No. 1921
Tank Capacity 0.5 lit Temperature
Setting Range
10 to 60°C ( water )
Constant-Temperature Accuracy ±0.2°C Temperature control PID control method using a thermo-module
Power Consumption 430VA Flow Rate 4 lit / min
Power Supply AC 100 to 240V, 50/60Hz Dimensions & Weight 38×24×27cm, 11.0kg
(Main Unit only)
Catalog Download
Go to the product search GO TOP

Digital printer DP-21(A)

The DP-21(A) is a printer for Multi-wavelength Abbe Refractometer DR-M2, DR-M4, DR-M2/1550 and DR-M4/1550 (Serial No.~092031).
It automatically prints out the number of samples, measurement results, and measured temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-21(A) Cat.No. 3011
Printing Method Thermal dot printing Power Supply From AC adapter
( for the printer )
Power Consumption 26VA Dimensions & Weight 14×10×4cm, 390g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper for DP-21(A) : RE-8413
Printer paper (long-term storage) for DP-21(A) : RE-8415
Go to the product search GO TOP

Digital printer DP-22(B)

The DP-22(B) is a printer for Multi-wavelength Abbe Refractometer DR-M2, DR-M4, DR-M2/1550 and DR-M4/1550 (Serial No.092101~).
It automatically prints out the number of samples, measurement results, and measured temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-22(B) Cat.No. 3125
Printing Method Thermal dot printing Power Supply From AC adapter
( for the printer )
Power Consumption 26VA Dimensions & Weight 14×10×4cm, 390g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper for DP-22(B) : RE-8413
Printer paper (long-term storage) for DP-22(B) : RE-8415
Go to the product search GO TOP